COMP (SC18CLX.2) 교체 서비스 노트
Original Content
How to change from the COMP (CA2435Z) to COMP (SC18CLX.2) — have to adjust the SUCTION PIPE B & DRAIN PIPE:
- If you want to replace the COMP from CA2435Z to SC18CLX2, you have to adjust the shape of the SUCTION PIPE B slightly.
- Because CA2435Z Drain Pipe is more bigger than SC18CLX2, so you need to adjust the shape of Drain Pipe like a picture to connect with COMP (SC18CLX2).
- COMP (SC18CLX.2): It is the way to connect Comp Relay & Start Capacitor to COMP (SC18CLX2).
(원본에 배관 형상 조정 사진·배선 다이어그램 포함 — 텍스트 추출에서는 누락.)
Open Question
Open Question
- 이 교체가 필요한 대상 모델(어떤 제품이 CA2435Z→SC18CLX.2 세대교체를 겪는지)이 명시되지 않음.